Construction |
| |
ATC-101 Interface: RS-232 to RS-422 Converter |
| |
ATC-106 Interface: RS-232 to RS-485 Converter |
• |
Connectors |
| |
RS-232: DB-9 female |
| |
ATC-101 RS-422: DB9 male |
| |
ATC-106 RS-485 DB-9 male or a terminal block |
• |
Signals |
| |
ATC-101 RS-232 Side : DB-9 Female Signals: Use Pins 3 (TD) and 2 (RD).
Pins 7 (RTS) and 8 (CTS) are tied together Pins 4 (DTR), 6 (DSR), and 1 (CD) are tied together. |
| |
ATC-106 RS-232 Side: Use Pins 3 (RD) and pin 2(TD also called SD) Pins 7 (RTS) and
8 (CTS) are tied together Pins 4 (DTR), 6 (DSR), and 1 (CD) are tied together. |
| |
ATC-101 RS-422 Side : DB9 Male connector—PIN1 (T-) PIN2 (T+), PIN3 (R+), PIN4 (R-),
6 position terminal
block -- +12V, GND, T+,T-,R+,R- Signals: Full-duplex 4-wire operation only Driver and Receiver are enabled
all the time. |
| |
ATC-106 RS-485 Side: 4 position terminal block - 485, +485-, +5V, GND |
• |
Data Rate: 300 to 115.2 KBPS, up to 4,000 feet at 19,200 BPS |
• |
Operating Distance |
| |
Maximum Distance (feet): 4,000 6,000 8,000 10,000(using 24 AWG wire) |
• |
Power: powered from the RS-232 data TD or handshake lines |
• |
Operation Temperature: 0° to 50° C, 5% to 95% relative humidity |
• |
Dimensions: 88 x 33 x 17 mm |